Negative Air Machine:Air Flow: 250 to 500 CFM with variable speed control
(w/ filters in place)
Power 115V, 60 Hz, 12 amp circuit breaker
Motor Impeller with thermal overload protection rated for
1000 CFM. 3 amps
GFCI Outlets 9 amp auxiliary outlet (12 amps with unit off)
Cord Length 25’
Dimensions 24.6” × 26.2” × 18.2”
Weight 44 lbs (19.9 kg)
Duct Size Intake: 12”, Outlet: 8”
Daisy chain Plug three units together – provides up to 1500 CFM
Housing Rotomolded polyethylene
Fire Rating Passes flammability testing UL94
Filter Change Light Indicates when HEPA filter needs to be changed
Safety marks UL/C-UL Listed
Filtration: 3 Stage DOP Compliant HEPA
- Pre Filter (included)
- DOP Filter (included)
- HEPA Filter (included)
- Carbon Filter (optional)